From 10c0e15fcd75fef2cdfb2103c99d9616f9edbe54 Mon Sep 17 00:00:00 2001
From: Wenqing Wang <wenqing.wang@ufz.de>
Date: Thu, 4 Mar 2021 12:53:44 +0100
Subject: [PATCH] [Test/TH2_PP] Replaced the old thermal conductivity input
 with MPL

---
 .../Twophase_HeatPipe_quad_curve_large.prj       | 16 ++++++++++++++++
 .../Twophase_HeatPipe_quad_curve_small.prj       | 16 ++++++++++++++++
 2 files changed, 32 insertions(+)

diff --git a/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_large.prj b/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_large.prj
index b936efdde7a..e87b53fdbc9 100644
--- a/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_large.prj
+++ b/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_large.prj
@@ -155,6 +155,12 @@
                     <type>Constant</type>
                     <value>1e-12</value>
                 </property>
+                <property>
+                    <name>thermal_conductivity</name>
+                    <type>SoilThermalConductivitySomerton</type>
+                    <dry_thermal_conductivity>k_T_dry</dry_thermal_conductivity>
+                    <wet_thermal_conductivity>k_T_wet</wet_thermal_conductivity>
+                </property>
             </properties>
         </medium>
     </media>
@@ -229,6 +235,16 @@
             <type>Constant</type>
             <values>1e-12</values>
         </parameter>
+        <parameter>
+            <name>k_T_dry</name>
+            <type>Constant</type>
+            <value>0.582</value>
+        </parameter>
+        <parameter>
+            <name>k_T_wet</name>
+            <type>Constant</type>
+            <value>1.14</value>
+        </parameter>
     </parameters>
     <time_loop>
         <processes>
diff --git a/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_small.prj b/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_small.prj
index 80e547102a8..343acf90182 100644
--- a/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_small.prj
+++ b/Tests/Data/Parabolic/ThermalTwoPhaseFlowPP/HeatPipe/Twophase_HeatPipe_quad_curve_small.prj
@@ -155,6 +155,12 @@
                     <type>Constant</type>
                     <value>1e-12</value>
                 </property>
+                <property>
+                    <name>thermal_conductivity</name>
+                    <type>SoilThermalConductivitySomerton</type>
+                    <dry_thermal_conductivity>k_T_dry</dry_thermal_conductivity>
+                    <wet_thermal_conductivity>k_T_wet</wet_thermal_conductivity>
+                </property>
             </properties>
         </medium>
     </media>
@@ -229,6 +235,16 @@
             <type>Constant</type>
             <values>1e-12</values>
         </parameter>
+        <parameter>
+            <name>k_T_dry</name>
+            <type>Constant</type>
+            <value>0.582</value>
+        </parameter>
+        <parameter>
+            <name>k_T_wet</name>
+            <type>Constant</type>
+            <value>1.14</value>
+        </parameter>
     </parameters>
     <time_loop>
         <processes>
-- 
GitLab