Skip to content

[BHE/2U] update documentation descriptions for 2U-type BHE

Shuang Chen requested to merge ShuangChen88/ogs:BHE_2U into master

When applying the power type BHE boundary condition for 2U-type BHE, the specified power value in the project file refers to the power provided by each U-pipe within the BHE, but not by the entire borehole exchanger. In this MR, several descriptions are added in the BHE user-guide and 2U-type BHE benchmark, targeting to notice the user to specify a correct power value when applying a power type BHE boundary condition.

Detailed changes are list below:

  1. Add the description for power type BHE boundary condition for 2U-type BHE in BHE user guide.
  2. Add the notice comment in the 2U-type BHE benchmark prj file.
  3. the key word 'heat capacity' of grout has been updated to 'specific heat capacity'.
Edited by Shuang Chen