Skip to content

LIE mohr coulomb load path test cleanup

I was a little to fast to merge the original MR !3221 (merged) For some reason the sigma_xy tests do not pass the given tolerances in the master's pipline. New references are provided showing same displacement and displacement jump fields. Tried with slightly other reference files, but got the same error range for sigma_xy. Relaxing the tolerances here: The sigma_xy range is O(1e4) with errors of O(1e-3) there is still O(1e-7) relative error.

See individual commit messages for details. Mostly cleanup.

Edited by Dmitry Yu. Naumov