* \file
*
* \copyright
* Copyright (c) 2012-2018, OpenGeoSys Community (http://www.opengeosys.org)
* Distributed under a Modified BSD License.
* See accompanying file LICENSE.txt or
* http://www.opengeosys.org/project/license
*
*/
#include "BaseLib/ConfigTree.h"
#include "MathLib/InterpolationAlgorithms/PiecewiseLinearInterpolation.h"
#include "BaseLib/Algorithm.h"
#include "CreateFlowAndTemperatureControl.h"
#include "RefrigerantProperties.h"
namespace ProcessLib
{
namespace HeatTransportBHE
{
namespace BHE
{
FlowAndTemperatureControl createFlowAndTemperatureControl(
BaseLib::ConfigTree const& config,
std::map<std::string,
std::unique_ptr<MathLib::PiecewiseLinearInterpolation>> const&
curves,
RefrigerantProperties const& refrigerant)
{
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__type}
auto const type = config.getConfigParameter<std::string>("type");
if (type == "TemperatureCurveConstantFlow")
{
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__TemperatureCurveConstantFlow__flow_rate}
double const flow_rate = config.getConfigParameter<double>("flow_rate");
auto const& temperature_curve = *BaseLib::getOrError(
curves,
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__TemperatureCurveConstantFlow__temperature_curve}
config.getConfigParameter<std::string>("temperature_curve"),
"Required temperature curve not found.");
return TemperatureCurveConstantFlow{flow_rate, temperature_curve};
}
if (type == "FixedPowerConstantFlow")
{
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerConstantFlow__power}
double const power = config.getConfigParameter<double>("power");
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerConstantFlow__flow_rate}
double const flow_rate = config.getConfigParameter<double>("flow_rate");
return FixedPowerConstantFlow{flow_rate, power,
refrigerant.specific_heat_capacity,
refrigerant.density};
}
if (type == "FixedPowerFlowCurve")
{
auto const& flow_rate_curve = *BaseLib::getOrError(
curves,
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerFlowCurve__flow_rate_curve}
config.getConfigParameter<std::string>("flow_rate_curve"),
"Required flow rate curve not found.");
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerFlowCurve__power}
double const power = config.getConfigParameter<double>("power");
return FixedPowerFlowCurve{flow_rate_curve, power,
refrigerant.specific_heat_capacity,
refrigerant.density};
}
OGS_FATAL("FlowAndTemperatureControl type '%s' is not implemented.",
type.c_str());
}
} // namespace BHE
} // namespace HeatTransportBHE
} // namespace ProcessLib
......@@ -11,7 +11,21 @@
#pragma once
#include "RefrigerantProperties.h"
#include <map>
#include <memory>
#include <string>
#include "FlowAndTemperatureControl.h"
namespace BaseLib
{
class ConfigTree;
}
namespace MathLib
{
class PiecewiseLinearInterpolation;
}
namespace ProcessLib
{
......@@ -19,70 +33,14 @@ namespace HeatTransportBHE
{
namespace BHE
{
struct RefrigerantProperties;
FlowAndTemperatureControl createFlowAndTemperatureControl(
BaseLib::ConfigTree const& config,
std::map<std::string,
std::unique_ptr<MathLib::PiecewiseLinearInterpolation>> const&
curves,
RefrigerantProperties const& refrigerant)
{
auto find_curve_or_error = [&](std::string const& name,
std::string const& error_message)
-> MathLib::PiecewiseLinearInterpolation const& {
auto const it = curves.find(name);
if (it == curves.end())
{
ERR(error_message.c_str());
OGS_FATAL(
"Curve with name '%s' could not be found in the curves list.",
name.c_str());
}
return *it->second;
};
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__type}
auto const type = config.getConfigParameter<std::string>("type");
if (type == "TemperatureCurveConstantFlow")
{
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__TemperatureCurveConstantFlow__flow_rate}
double const flow_rate = config.getConfigParameter<double>("flow_rate");
auto const& temperature_curve = find_curve_or_error(
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__TemperatureCurveConstantFlow__temperature_curve}
config.getConfigParameter<std::string>("temperature_curve"),
"Required temperature curve not found.");
return TemperatureCurveConstantFlow{flow_rate, temperature_curve};
}
if (type == "FixedPowerConstantFlow")
{
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerConstantFlow__power}
double const power = config.getConfigParameter<double>("power");
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerConstantFlow__flow_rate}
double const flow_rate = config.getConfigParameter<double>("flow_rate");
return FixedPowerConstantFlow{flow_rate, power,
refrigerant.specific_heat_capacity,
refrigerant.density};
}
if (type == "FixedPowerFlowCurve")
{
auto const& flow_rate_curve = find_curve_or_error(
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerFlowCurve__flow_rate_curve}
config.getConfigParameter<std::string>("flow_rate_curve"),
"Required flow rate curve not found.");
//! \ogs_file_param{prj__processes__process__HEAT_TRANSPORT_BHE__borehole_heat_exchangers__borehole_heat_exchanger__flow_and_temperature_control__FixedPowerFlowCurve__power}
double const power = config.getConfigParameter<double>("power");
return FixedPowerFlowCurve{flow_rate_curve, power,
refrigerant.specific_heat_capacity,
refrigerant.density};
}
OGS_FATAL("FlowAndTemperatureControl type '%s' is not implemented.",
type.c_str());
}
RefrigerantProperties const& refrigerant);
} // namespace BHE
} // namespace HeatTransportBHE
} // namespace ProcessLib