#===== r2ogs6_borehole_heat_exchanger =====
#'r2ogs6_borehole_heat_exchanger
#'@description tag: borehole_heat_exchanger
#'@param type string:
#'@param flow_and_temperature_control r2ogs6_flow_and_temperature_control:
#'@param borehole list:
#'@param grout list:
#'@param pipes r2ogs6_pipes:
#'@param refrigerant list:
#'@param use_bhe_pipe_network Optional: string ("true" | "false"):
#'@export
r2ogs6_borehole_heat_exchanger <- function(type,
flow_and_temperature_control,
borehole,
grout,
pipes,
refrigerant,
use_bhe_pipe_network = NULL) {
# Add coercing utility here
new_r2ogs6_borehole_heat_exchanger(type,
flow_and_temperature_control,
borehole,
grout,
pipes,
refrigerant,
use_bhe_pipe_network)
}
new_r2ogs6_borehole_heat_exchanger <- function(type,
flow_and_temperature_control,
borehole,
grout,
pipes,
refrigerant,
use_bhe_pipe_network = NULL) {
assertthat::assert_that(class(flow_and_temperature_control) ==
"r2ogs6_flow_and_temperature_control")
borehole <- coerce_names(borehole, c("length", "diameter"))
grout <- coerce_names(grout, c("density",
"porosity",
"specific_heat_capacity",
"thermal_conductivity"))
assertthat::assert_that(class(pipes) == "r2ogs6_pipes")
refrigerant <- coerce_names(refrigerant, c("density",
"viscosity",
"specific_heat_capacity",
"thermal_conductivity",
"reference_temperature"))
are_null_or_string_flags(use_bhe_pipe_network)
structure(list(type = type,
flow_and_temperature_control = flow_and_temperature_control,
borehole = borehole,
grout = grout,
pipes = pipes,
refrigerant = refrigerant,
use_bhe_pipe_network = use_bhe_pipe_network,
xpath = paste0("processes/process/borehole_heat_exchangers/",
"borehole_heat_exchanger"),
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
attr_names = character(),
flatten_on_exp = character()
),
class = "r2ogs6_borehole_heat_exchanger"
)
}
#===== r2ogs6_flow_and_temperature_control =====
#'r2ogs6_flow_and_temperature_control
#'@description tag: flow_and_temperature_control
#'@param type string:
#'@param flow_rate Optional: string | double:
#'@param temperature_curve Optional: string:
#'@param power Optional: string | double:
#'@param power_curve Optional: string:
#'@param flow_rate_curve Optional: string:
#'@export
r2ogs6_flow_and_temperature_control <- function(type,
flow_rate = NULL,
temperature_curve = NULL,
power = NULL,
power_curve = NULL,
flow_rate_curve = NULL) {
# Coerce input
flow_rate <- coerce_string_to_numeric(flow_rate)
power <- coerce_string_to_numeric(power)
new_r2ogs6_flow_and_temperature_control(type,
flow_rate,
temperature_curve,
power,
power_curve,
flow_rate_curve)
}
new_r2ogs6_flow_and_temperature_control <- function(type,
flow_rate = NULL,
temperature_curve = NULL,
power = NULL,
power_curve = NULL,
flow_rate_curve = NULL) {
are_null_or_strings(temperature_curve,
power)
structure(list(type = type,
flow_rate = flow_rate,
temperature_curve = temperature_curve,
power = power,
power_curve = power_curve,
flow_rate_curve = flow_rate_curve,
xpath = paste0("processes/process/borehole_heat_exchangers/",
"borehole_heat_exchanger/",
"flow_and_temperature_control"),
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
attr_names = character(),
flatten_on_exp = character()
),
class = "r2ogs6_flow_and_temperature_control"
)
}
#===== r2ogs6_pipes =====
#'r2ogs6_pipes
#'@description tag: pipes
#'@param longitudinal_dispersion_length string | double:
#'@param inlet Optional: list:
#'@param outlet Optional: list:
#'@param distance_between_pipes Optional: string | double:
#'@param outer Optional: list:
#'@param inner Optional: list:
#'@export
r2ogs6_pipes <- function(longitudinal_dispersion_length,
inlet = NULL,
outlet = NULL,
distance_between_pipes = NULL,
outer = NULL,
inner = NULL) {
# Coerce input
longitudinal_dispersion_length <-
coerce_string_to_numeric(longitudinal_dispersion_length)
distance_between_pipes <-
coerce_string_to_numeric(distance_between_pipes)
new_r2ogs6_pipes(longitudinal_dispersion_length,
inlet,
outlet,
distance_between_pipes,
outer,
inner)
}
new_r2ogs6_pipes <- function(longitudinal_dispersion_length,
inlet = NULL,
outlet = NULL,
distance_between_pipes = NULL,
outer = NULL,
inner = NULL) {
are_numbers(longitudinal_dispersion_length)
inlet_outlet_names <- c("diameter",
"wall_thickness",
"wall_thermal_conductivity")
inlet <- is_null_or_coerce_names(inlet, inlet_outlet_names)
outlet <- is_null_or_coerce_names(outlet, inlet_outlet_names)
are_null_or_numbers(distance_between_pipes)
outer <- is_null_or_coerce_names(outer, inlet_outlet_names)
inner <- is_null_or_coerce_names(inner, inlet_outlet_names)
structure(list(longitudinal_dispersion_length =
longitudinal_dispersion_length,
inlet = inlet,
outlet = outlet,
distance_between_pipes = distance_between_pipes,
outer = outer,
inner = inner,
xpath = paste0("processes/process/borehole_heat_exchangers/",
"borehole_heat_exchanger/pipes"),
attr_names = character(),
flatten_on_exp = character()
),
class = "r2ogs6_pipes"
)
}